Natural Gas (NGV) Refueling Stations & Component Systems, Universal Air Products Corp., Norfolk, VA Universal Air Products Corp. - Natural Gas (NGV) Refueling Stations & Component Systems
Call Us Today: 800.326.8406  |  Email Us: info@uapc.com
Custom Compression
Systems & Components
All Categories > Natural Gas (NGV) Refueling Stations & Component Systems 
    Printable Page     Email Email This Page     Save To Favorites Save To Favorites
Compressor System Application

Natural Gas (NGV) Refueling Stations & Component Systems



    Email Email This Page  
    Save To Favorites Save To Favorites
  

NGV

larger image
Universal Air & Gas Products Corporation (UAPC) has decades of successful experience in turn-key, natural gas fuel system design and construction. Gas compression, storage, dispensing, regulation and controls are all available from UAPC. Similar expertise is applied to government, military and industry applications. These applications include natural gas (NGV) systems built to virtually any USA or international standard.

The services that we provide for the production of natural gas refueling stations or component systems are:
  • Consulting
  • Station design/engineering services
  • In house CAD design capabilities
  • Standard and custom designed compression packages
  • Supply of state of the art fuel dispensing systems
  • Supply of ASME & DOT gas storage systems
  • Supply of card readers
  • Construction management
Certified field service technicians and engineers support UAPC systems during installation and startup. As needed or long-term maintenance agreements are also available, which provide for routine or comprehensive technical site supervision. Documentation packages are extensive. This facilitates detailed maintenance, appropriate




Specifications · Standard NG Compression Systems · Additional Information

Specifications

Compressor Types

Duplex (Multiple Compressors)
Reciprocating
Rotary
Rotary Vane

Lubrication Options

Oil Lubricated
Oil-Free
Oil-Less

Cooling Options

Air Cooled Aftercooler
Air Cooled Compressor Block
Air Cooled Entirely
Air Cooled Intercooler (If Multi-Staged)
Water Cooled Aftercooler
Water Cooled Compressor Block
Water Cooled Entirely
Water Cooled Intercooler (If Multi-Staged)

Installation Site

Hazardous (Explosive gas or dust potentially present)
Inside
Inside-Water Exposed
Outside
Outside-Salt Air Exposed
Outside-Weather Exposed

Drive Type

Electric
Gas

Electrical Standards:

NEMA
IEC (International Electrotechnical Commission)
IP Code (International Protection Rating)
CSA (Canadian Standards Association)

Electric Motor Standards

IEC Standard
NEMA Standard

Electric Motor Options

Direct Coupled
Explosion Proof
Flexible V-Belt Drive
Fungus Protection
Mill & Chemical Duty
Open Drip Proof (ODP)
Space Heater
Totally Enclosed Fan Cooled (TEFC)

Gas Dryer Options

Desiccant dryer
Membrane dryer
Others
Refrigerated dryer

Pressure Vessel Standards

ASME
California Seismic Zone
California-LA Code
Massachusetts code
Others
TUV

Pressure Vessel Materials

Carbon steel, enamel exterior finish only
Carbon steel, epoxy-coated interior/exterior
Carbon steel, epoxy-lined interior
Others
Stainless steel, 304
Stainless steel, 316


Standard NG Compression Systems

Standard NG Compression System Models

Duplex, Enclosed Compressor Systems
Enclosed Compressor Systems
Large Compressor System (Air Cooled)
Large Compressor Systems (Water Cooled)
Small Compressor Systems

Power (Electric Motor) Range

5 to 300 hp

Inlet Pressure

1 inch WC or higher

Maximum Discharge Pressure

6000 psig

Flow (Subject to Inlet/Outlet Conditions) Rate

5 to 1030 scfm

Compression Stages

3 to 5, Subject to Inlet Conditions

Cooling System Design Options

Air
Water

Electrical Classification (USA)

NEC NEMA Design 7, Class 1, Division 2, Group C, D

Electrical Voltage

200 to 575 V

Electrical Phase (Ph)

1 Ph to 10HP
3 Ph all HP

Standard Compression System Features

  • Structural steel base frame, fork-liftable
  • Full system steel enclosure with oil-resistant, sound and ambient insulation; ventilation louvers and fans; pitched roof with ridge vents, heat reflective roof panels; lift-off (trigger latch) 16 gauge steel access panels
  • PLC (programmable logic control)
  • Digital message board with fault history and real time readings for all sensors
  • Common fault indicator light for programmed shutdown conditions
  • Full voltage motor starter and electrical control system mounted and wired
  • Control voltage circuit with step-down transformer
  • Motor overloads
  • Power-on light
  • Emergency kill (mushroom) switch
  • On-off switch for start/stop control (two-way switch)
  • Face gauge panel, including 1st stage thru final discharge pressure and oil pressure
  • Face gauge for final system pressure prior to the pressure maintaining valve
  • Discharge pressure sensor with infinite setting control and multiple set points
  • Low and high inlet pressure sensor
  • Low oil pressure sensor
  • High outlet temperature sensor (1st & 4th stages)
  • Contacts provided for remote monitoring of system controls
  • Built-in air cooled intercoolers and aftercooler
  • Moisture separation, all stages
  • Auto condensate drainage, all stages
  • Cartridge dryer / filtration manifold, installed
  • Forced lubrication system with oil pump and filter
  • Crankcase breather piped to inlet or vent (subject to inlet conditions)
  • Automatic compressor unloading system with vented to vapor recovery tank
  • Non-return valve at discharge
  • Minimum pressure valve at discharge
  • Finish paint in blue or light gray enamel
  • ASME, inlet gas surge tank with pressure gauge and gas tight relief valve
  • Integrated vapor recovery system with ASME storage vessel regulated to system inlet
  • Detailed general arrangement, electrical and flow diagrams for customer review and approval prior to system construction
  • Detailed operations, maintenance and parts manuals provided in electronic or hard copy format (Standard English, alternate languages available at option)

Compression System Options

  • Completely custom designs
  • Larger horse power ( kW)
  • Loose starter and/or electrical controls for mounting remotely at the job site
  • Reduced voltage starter (wye-delta, solid state or VFD)
  • Wired / wireless (LAN and/or WAN) based controls with monitoring capabilities (HMI and/or SCADA)
  • Combination style disconnect switch for the motor starter
  • Inlet pressure regulation
  • Outlet pressure regulation
  • Off-shore base frame (skid) design with lifting eye and drag provisions
  • Vapor recovery tank pressure or temperature sensors
  • Analog controls rather than PLC
  • Custom programming of the PLC
  • Inlet or discharge gas filtration
  • Finish paint in epoxy and/or customer’s color selection
  • Hot dip galvanized structural steel base frame
  • Installation & startup
  • Aftermarket technical support or site services
  • Manuals provided in languages other than English
  • Closed loop air to water heat exchanger
  • Closed loop salt water to fresh water heat exchanger
  • Closed loop water chiller
  • Open frame design (Elimination of the full system enclosure)
  • Others


Additional Information

Services

Design
Installation
Maintenance
Manufacturing
Overhaul or Reconfiguration
Repair
Testing and Certification

Industries Served

Fire Services
Food & Chemical Processing
General Industrial & Commercial Customers
Marine
Medical
Military
Offshore
Pet

Certifications

ASME
DOT Certified


 MORE IMAGES 

· NGV - 1

· NGV - 2

· NGV - 3

· NGV - 4

· NGV - 5

· NGV - 6

· NGV - 7

· NGV - 8

· NGV - 9

· NGV - 10

· NGV - 11

· NGV - 12


 DOWNLOADS 

 width= 5 to 50 HP Compressor System, Air Cooled
(PDF, 121KB)

 width= 5 to 50 HP Enclosed Compressor System, Air Cooled
(PDF, 89KB)

 width= 10 to 100 HP Duplex Enclosed Compressor System, Air Cooled
(PDF, 626KB)

 width= 20 to 200 HP Compressor System, Water Cooled
(PDF, 89KB)

 width= 60 to 300 HP Compressor System, Air Cooled
(PDF, 88KB)


Compressor System Application
Universal Air & Gas Products Corp. | Quality 
Equipment & Service Since 1962