Item # Mi-16, Self-Contained Standard Precipitators - 1600 CFM



Self-Contained Standard Precipitators - Model Series: Mi (with Integral Blower/Motor Assembly)- 800 Though 6000 CFM

Mi-series: This product range is self-contained, utilizing its own built in squirrel cage blower and motor assembly. Typically the units are free standing or suspended from the ceiling. Source capture applications use a pickup hose assembly to draw mist or smoke directly from it source and into the precipitator for cleaning much like a vacuum cleaner.





Specifications  · Blower Motor  · Power Requirements  · Air Cleaner Specifications  · Ionizer Specifications  · Other Options Available  · Additional Information  · Note  · SEO

Specifications

Nominal Rating1

45.3 m³/min
1600
ft³/min

Cabinet Material

16 gauge, Cold Rolled Steel (Std.)
Primed with Enamel Finish

Cell(s) Material

Aluminum (Std.)
Hastelloy

Stainless Steel

Unit Weight

300 lb

Height

23 in

Length

41.5 in

Width

36 in

Inlet Duct Height

15.5 in

Inlet Duct Width

33.375 in

Outlet Duct Height

10 in

Outlet Duct Width

29 in

Collecting Cell Height

18 in

Collecting Cell Width

17.125 in

Collecting Cell Depth

12.563 in

Collecting Cell Weight

26 lb

Unit Operating Current Range

0.9 to 1.3 mA

Collector Direct Current (DC) Voltage

7200 to 8800 V

Ionizer Voltage Gradient (DC) at 8000 Volt (V) Direct Current (DC) Voltage

11158 V/in

Collector Voltage Gradient (DC) at 8000 Volt (V) Direct Current (DC) Voltage

24768 V/in

Collector Plates Insulator and Diameter

Collector plates are suspended with four, 2.25" diameter ceramic insulators.

Power Pack Description

Solid state design, controls include: circuit breaker with manual reset, LED
Power on light, ammeter, variable rheostat, safety interlock switch. Power packs can be unit or remote mounted.

Power Package Quantity

1

Pre & Post Filter

Washable, aluminum mesh mechanical pre-and post cell filters.
1 Consult with factory or an authorized representative for proper model selection.


Blower Motor

Motor Type

Open Drip Proof (ODP) (Standard)
Totally Enclosed, Fan-Cooled (TEFC)

Motor Power

1/3 hp

Motor Speed

1725 rpm

Electrical Design

50 Hz or NEMA 3, 4, 4X or 12
NEMA 1, 60 Hz (Std)

Motor Drive Design

Flexible V-Belt
Variable Sheave

Blower Type

Forward cure with sealed ball bearings mounted with rubber grommets to reduce noise and vibration; belt driven.

Blower Power

750 rpm


Power Requirements

Voltage

115 V
220
V

Frequency

50 Hz
60
Hz

Phase

1


Air Cleaner Specifications

Air Cleaner Type

Two stage, dry, electrostatic precipitator

Efficiency

Atmospheric dust spot 91%; Cold DOP 96%

Efficiency Test Method

ASHRAE 52-76

Quantity at Cell Size - Each

2 x 800 ft³/min

Total Collector Plate Surface

15224 in²

Plate Spacing

0.323 in

Air Velocity

415 ft/min


Ionizer Specifications

Ionizer Direct Current (DC) Voltage

7200 to 8800 V

Ionizer Type

Integral to collecting cell, supported without ceramic insulators, tungsten wire electrodes (standard), optional electrode materials available.

Ionizer Electrode Diameter

0.007 in

Ionizer Suspension

Stainless steel wire springs at each electrode end.


Other Options Available

Water Wash Manifolds

Copper manifold (pipe) with wide angle spray nozzles; single side wash.

System Cleaning

Fully Automatic Wash and Dry Cycle with or without detergent injection.
Manually Initiated

Source Capture Plenums

Specifically designed for the application

Filter Manifolds

Pre and post filter racks designed per requirement for HEPA or charcoal.

Electrical Controls

Custom designed options in relay logic or PLC


Additional Information
Mi-series units are built only with industrial cells as described above under the I-series. Blower and motor assemblies are designed to accommodate the SCFM throughput of the application with consideration for internal and external static pressure losses. Mi-series housings are made of cold rolled steel that is primed and finished in enamel. Single tier and two tier configurations are available in sizes ranging from 800-CFM to 6000-CFM.



Note
Technical data and design features are subject to change without prior notification
Consult factory for larger models.



SEO

Manufacturer

Universal Air & Gas


 DOWNLOADS 

Installation, Operational, and Service Manual
(PDF, 41KB)

Brochure for Self-Contained Standard Precipitators - 800 Though 6000 CFM
(PDF, 918KB)

Technical Data for Self-Contained Standard Precipitators - 800 Though 6000 CFM
(PDF, 29KB)

Self-Contained Standard Precipitators Equipment & Option Prices
(PDF, 54KB)

Features
(PDF, 41KB)

Parts & Component Prices
(PDF, 49KB)

Custom Products & Features
(PDF, 867KB)

Datasheet (Mi-16h1)
(DOC, 205KB)

Mi-16 Dimensions
(PDF, 224KB)


Universal Air & Gas Products Corp. | Quality 
Equipment & Service Since 1962