Standard Compression System Models
|
N/A
Duplex, Enclosed Compressor Systems Enclosed Compressor Systems Large Compressor System (Air Cooled) Large Compressor Systems (Water Cooled) Small Compressor Systems
|
Power (Electric Motor) Range
|
N/A
5 to 300 hp
|
Inlet Pressure
|
N/A
1 inch WC or higher
|
Maximum Discharge Pressure
|
N/A
6000 psig
|
Flow (Subject to Inlet/Outlet Conditions) Rate
|
N/A
5 to 1030 scfm
|
Compression Stages
|
N/A
3 to 5, Subject to Inlet Conditions
|
Cooling System Design Options
|
N/A
Air Water
|
Electrical Classification (USA)
|
N/A
NEC NEMA Design 7, Class 1, Division 2, Group C, D
|
Electrical Voltage
|
N/A
200 to 575 V
|
Electrical Phase (Ph)
|
N/A
1 Ph to 10 HP 3 Ph all HP
|
Standard Compression System Features
|
N/A
- Structural steel base frame, fork-liftable
- Full system steel enclosure with oil-resistant, sound and ambient insulation; ventilation louvers and fans; pitched roof with ridge vents, heat reflective roof panels; lift-off (trigger latch) 16 gauge steel access panels
- PLC (programmable logic control)
- Digital message board with fault history and real time readings for all sensors
- Common fault indicator light for programmed shutdown conditions
- Full voltage motor starter and electrical control system mounted and wired
- Control voltage circuit with step-down transformer
- Motor overloads
- Power-on light
- Emergency kill (mushroom) switch
- On-off switch for start/stop control (two-way switch)
- Face gauge panel, including 1st stage thru final discharge pressure and oil pressure
- Face gauge for final system pressure prior to the pressure maintaining valve
- Discharge pressure sensor with infinite setting control and multiple set points
- Low and high inlet pressure sensor
- Low oil pressure sensor
- High outlet temperature sensor (1st & 4th stages)
- Contacts provided for remote monitoring of system controls
- Built-in air cooled intercoolers and aftercooler
- Moisture separation, all stages
- Auto condensate drainage, all stages
- Cartridge dryer / filtration manifold, installed
- Forced lubrication system with oil pump and filter
- Crankcase breather piped to inlet or vent (subject to inlet conditions)
- Automatic compressor unloading system with vented to vapor recovery tank
- Non-return valve at discharge
- Minimum pressure valve at discharge
- Finish paint in blue or light gray enamel
- ASME, inlet gas surge tank with pressure gauge and gas tight relief valve
- Integrated vapor recovery system with ASME storage vessel regulated to system inlet
- Detailed general arrangement, electrical and flow diagrams for customer review and approval prior to system construction
- Detailed operations, maintenance and parts manuals provided in electronic or hard copy format (Standard English, alternate languages available at option)
|
Compression System Options
|
N/A
- Completely custom designs
- Larger horse power ( kW)
- Loose starter and/or electrical controls for mounting remotely at the job site
- Reduced voltage starter (wye-delta, solid state or VFD)
- Wired / wireless (LAN and/or WAN) based controls with monitoring capabilities (HMI and/or SCADA)
- Combination style disconnect switch for the motor starter
- Inlet pressure regulation
- Outlet pressure regulation
- Off-shore base frame (skid) design with lifting eye and drag provisions
- Vapor recovery tank pressure or temperature sensors
- Analog controls rather than PLC
- Custom programming of the PLC
- Inlet or discharge gas filtration
- Finish paint in epoxy and/or customer's color selection
- Hot dip galvanized structural steel base frame
- Installation & startup
- Aftermarket technical support or site services
- Manuals provided in languages other than English
- Closed loop air to water heat exchanger
- Closed loop salt water to fresh water heat exchanger
- Closed loop water chiller
- Open frame design (Elimination of the full system enclosure)
- Others
|