Zero-loss, electronically operated drain valve, specially designed to drain condensate.

Energy Saving Technology
The intelligent drain function monitors condensate build-up with liquid level sensors and evacuates the condensate only when necessary, thereby avoiding compressed air waste and providing for considerable energy savings.

Peace of Mind
Condensate drain device offers security and confidence, enabling you to solve all condensate discharge problems even in heavily contaminated systems.

Reliable Air Treatment Solutions

Reliable Air Treatment Solutions

N/A Pure compressed air according to ISO standard
Depending on the application air with specified purity is needed. We offer filters with performance from 720 to 40500 l/min, with filtration class from 3 to 0.01 micrometers, capable to provide the required air purity in accordance with ISO 8573 and ISO 12500.

Air Treatment Solutions for All

Air Treatment Solutions for All

N/A We have air treatment solutions for all businesses, so trust in us for your next air treatment purchase. Air treatment reduces costs, prevents tool degeneration and dangerous substances in your drain water. With distributors all across the United States, get your next air treatment solution with us and continue your compressed air production with the peace of mind that you are protected.

Vitrified Vessels (Vitroflex)

Vitrified Vessels (Vitroflex)

N/A Condensate enters the drain and collects in sump. The diaphragm valve is closed due to the solenoid valve allowing pressure compensation through the pilot supply line. The pressurized space above the diaphragm is larger than that below it, ensuring and absolutely leak proof seal. As the condensate drains away, the level probe monitors the speed at which the level drops, calculating exactly when to shut the diaphragm, so that no air escapes. If there should be a blockage on the outlet or faulty diaphragm, the drain switched to “fault mode”. Both the flashing alarm light and the volt free contact are activated. The drain switches to a “timer mode” until the situation is solved.

How Does a Condensate Drain Work?

How Does a Condensate Drain Work?

N/A Condensate enters the drain and collects in sump. The diaphragm valve is closed due to the solenoid valve allowing pressure compensation through the pilot supply line. The pressurized space above the diaphragm is larger than that below it, ensuring and absolutely leak proof seal. As the condensate drains away, the level probe monitors the speed at which the level drops, calculating exactly when to shut the diaphragm, so that no air escapes. If there should be a blockage on the outlet or faulty diaphragm, the drain switched to “fault mode”. Both the flashing alarm light and the volt free contact are activated. The drain switches to a “timer mode” until the situation is solved.

Additional Information

Additional Information

N/A Condensate management
Automatic condensate drainage removes the condensate from your compressed air network. Greatly reducing the risk of destructive wear of your air distribution system, not to mention the manual labor of doing timer condensate discharge.

Reliable
Using top quality technology and components, our air treatment products offer reliable solutions. Reliability from us, provide security for you.

Easy to operate
With easy access to critical components, our products offer easy to operate, easy to maintain solutions for all businesses.

Peace of mind
With our air treatment products we enhance peace of mind regarding your compressed air system. Air treatment reduce costs, prevents tool degeneration and dangerous substances in your drain water.