Self-Contained Standard Precipitators - Model Series: Mi (with Integral Blower/Motor Assembly)- 800 Though 6000 CFM
Mi-series: This product range is self-contained, utilizing its own built in squirrel cage blower and motor assembly. Typically the units are free standing or suspended from the ceiling. Source capture applications use a pickup hose assembly to draw mist or smoke directly from it source and into the precipitator for cleaning much like a vacuum cleaner.
Mi-series: This product range is self-contained, utilizing its own built in squirrel cage blower and motor assembly. Typically the units are free standing or suspended from the ceiling. Source capture applications use a pickup hose assembly to draw mist or smoke directly from it source and into the precipitator for cleaning much like a vacuum cleaner.
Unit of Measure
Specifications
|
Blower Motor
|
Power Requirements
|
Air Cleaner Specifications
|
Ionizer Specifications
|
Other Options Available
|
Additional Information
|
Note
|
SEO
Specifications
Nominal Rating1 | N/A 170 m³/min6000 ft³/min |
Cabinet Material |
N/A 16 gauge, Cold Rolled Steel (Std.) Primed with Enamel Finish |
Cell(s) Material |
N/A Aluminum (Std.) Hastelloy Stainless Steel |
Unit Weight |
N/A 700 lb |
Height |
N/A 41.25 in |
Length |
N/A 41.5 in |
Width |
N/A 65.75 in |
Inlet Duct Height |
N/A 33.75 in |
Inlet Duct Width |
N/A 62.25 in |
Outlet Duct Height |
N/A 12.25 in |
Outlet Duct Width |
N/A 14.375 in |
Collecting Cell Height |
N/A 18 in |
Collecting Cell Width |
N/A 21.25 in |
Collecting Cell Depth |
N/A 12.56 in |
Collecting Cell Weight |
N/A 32 lb |
Unit Operating Current Range |
N/A 1.5 to 2.1 mA |
Collector Direct Current (DC) Voltage |
N/A 7200 to 8800 V |
Ionizer Voltage Gradient (DC) at 8000 Volt (V) Direct Current (DC) Voltage |
N/A 11158 V/in |
Collector Voltage Gradient (DC) at 8000 Volt (V) Direct Current (DC) Voltage |
N/A 24768 V/in |
Collector Plates Insulator and Diameter |
N/A Collector plates are suspended with four, 2.25" diameter ceramic insulators. |
Power Pack Description |
N/A
Solid state design, controls include: circuit breaker with manual reset, LED Power on light, ammeter, variable rheostat, safety interlock switch. Power packs can be unit or remote mounted. |
Power Package Quantity |
N/A 2 |
Pre & Post Filter |
N/A Washable, aluminum mesh mechanical pre-and post cell filters. |
Blower Motor
Motor Type |
N/A Open Drip Proof (ODP) (Standard) Totally Enclosed, Fan-Cooled (TEFC) |
Motor Power |
N/A 1.5 hp |
Motor Speed |
N/A 1725 rpm |
Electrical Design |
N/A 50 Hz or NEMA 3, 4, 4X or 12 NEMA 1, 60 Hz (Std) |
Motor Drive Design |
N/A Flexible V-Belt Variable Sheave |
Blower Type |
N/A Forward cure with sealed ball bearings mounted with rubber grommets to reduce noise and vibration; belt driven. |
Blower Power |
N/A 700 rpm |
Air Cleaner Specifications
Air Cleaner Type |
N/A Two stage, dry, electrostatic precipitator |
Efficiency |
N/A Atmospheric dust spot 91%; Cold DOP 96% |
Efficiency Test Method |
N/A ASHRAE 52-76 |
Quantity at Cell Size - Each |
N/A 6 x 1000 ft³/min |
Total Collector Plate Surface |
N/A 57888 in² |
Plate Spacing |
N/A 0.323 in |
Air Velocity |
N/A 415 ft/min |
Ionizer Specifications
Ionizer Direct Current (DC) Voltage |
N/A 7200 to 8800 V |
Ionizer Type |
N/A Integral to collecting cell, supported without ceramic insulators, tungsten wire electrodes (standard), optional electrode materials available. |
Ionizer Electrode Diameter |
N/A 0.007 in |
Ionizer Suspension |
N/A Stainless steel wire springs at each electrode end. |
Other Options Available
Water Wash Manifolds |
N/A Copper manifold (pipe) with wide angle spray nozzles; single side wash. |
System Cleaning |
N/A Fully Automatic Wash and Dry Cycle with or without detergent injection. Manually Initiated |
Source Capture Plenums |
N/A Specifically designed for the application |
Filter Manifolds |
N/A Pre and post filter racks designed per requirement for HEPA or charcoal. |
Electrical Controls |
N/A Custom designed options in relay logic or PLC |
Additional Information
Additional Information |
N/A Mi-series units are built only with industrial cells as described above under the I-series. Blower and motor assemblies are designed to accommodate the SCFM throughput of the application with consideration for internal and external static pressure losses. Mi-series housings are made of cold rolled steel that is primed and finished in enamel. Single tier and two tier configurations are available in sizes ranging from 800-CFM to 6000-CFM. |
- 1 Consult with factory or an authorized representative for proper model selection.