Air Flow Capacity |
N/A 56.6 m³/min2000 ft³/min |
Rated Efficiency |
N/A 90 % |
Air Conditioner Capacity |
N/A 5 tons |
Air Flow Resistance (wg) |
N/A 0.1 in |
W - Width |
N/A 44 7/16 in |
X - Duct Opening |
N/A 40 15/16 in |
Y - Height |
N/A 23 in |
Z - Duct Height |
N/A 15 7/8 in |
Cell Removal Clearance |
N/A 25 in |
Approximate Shipping Weight |
N/A 200 lb |
Power Package Quantity |
N/A 1 |
Voltage |
N/A 115 V |
Frequency |
N/A 50 Hz60 Hz |
Power (Per Pack) |
N/A 45 W |
Water Inlet |
N/A 3/4 in |
Drain Flange (Iron Pipe Size (IPS)) |
N/A 2 in |
Water Required at 40 Pound per Square Inch (PSI) Per Tier |
N/A 20 gpm |
Additional Information |
N/A The C-series is just as efficient as the industrial or I-series, however it is not as mechanically sturdy. Due to its lower cost, some customers opt for the C-series over the I-series. In overview, the C-series cell uses eight tie rod supports for the collector plates; its ionizing section is supported without ceramic insulators; and its end plates are made of galvanized steel. Otherwise, the C-series cell has collector plates, spacers and an ionizing section that are identical with the materials and dimensions of the residential and industrial cell designs. |